Examples from OSM Hackfests: Difference between revisions
From OSM Public Wiki
Candelpreste (talk | contribs) No edit summary |
Candelpreste (talk | contribs) No edit summary |
||
Line 597: | Line 597: | ||
== VNF with Day-1/Day-2 configuration (adding a charm) == | == VNF with Day-1/Day-2 configuration (adding a charm) == | ||
* '''VNF | |||
* '''VNF package:''' [https://osm-download.etsi.org/ftp/osm-4.0-four/3rd-hackfest/packages/hackfest_simplecharm_vnf.tar.gz hackfest_simplecharm_vnf] | |||
* '''NS package:''' [https://osm-download.etsi.org/ftp/osm-4.0-four/3rd-hackfest/packages/hackfest_simlecharm_ns.tar.gz hackfest_simplecharm_ns] | |||
* '''Image hackfest3-mgmt:''' [https://osm-download.etsi.org/ftp/osm-3.0-three/1st-hackfest/images/hackfest3-mgmt.qcow2] | |||
* '''Reference material:''': | * '''Reference material:''': | ||
**[https://osm-download.etsi.org/ftp/osm- | **[https://osm-download.etsi.org/ftp/osm-4.0-four/3rd-hackfest/presentations/20180626%20OSM%20Hackfest%20-%20VNF%20and%20NS%20package%20generation%20from%20command%20line.pdf How to generate VNF package from command line] | ||
**[https://osm-download.etsi.org/ftp/osm- | **[https://osm-download.etsi.org/ftp/osm-4.0-four/3rd-hackfest/presentations/20180628%20OSM%20Hackfest%20-%20Session%207a%20-%20Adding%20day-1%20and%20day-2%20configuration%20to%20your%20VNF%20-%20Creating%20your%20first%20proxy%20charm.pdf Adding day-1/day-2 configuration to your VNF. Creating a charm for your VNF] | ||
**[https://osm-download.etsi.org/ftp/osm-4.0-four/3rd-hackfest/presentations/20180628%20OSM%20Hackfest%20-%20Session%207b%20-%20Adding%20Charms%20to%20your%20VNF%20Descriptor.pdf Adding charms to your VNF Descriptor] | |||
===VNF diagram=== | |||
[[File:Hackfest simplecharm vnf.JPG|500px]] | |||
===VNF descriptor=== | |||
vnfd:vnfd-catalog: | |||
vnfd: | |||
- id: hackfest-simplecharm-vnf | |||
name: hackfest-simplecharm-vnf | |||
short-name: hackfest-simplecharm-vnf | |||
version: '1.0' | |||
description: A VNF consisting of 2 VDUs connected to an internal VL, and one VDU with cloud-init | |||
logo: osm.png | |||
connection-point: | |||
- id: vnf-mgmt | |||
name: vnf-mgmt | |||
short-name: vnf-mgmt | |||
type: VPORT | |||
- id: vnf-data | |||
name: vnf-data | |||
short-name: vnf-data | |||
type: VPORT | |||
mgmt-interface: | |||
cp: vnf-mgmt | |||
internal-vld: | |||
- id: internal | |||
name: internal | |||
short-name: internal | |||
type: ELAN | |||
internal-connection-point: | |||
- id-ref: mgmtVM-internal | |||
- id-ref: dataVM-internal | |||
vdu: | |||
- id: mgmtVM | |||
name: mgmtVM | |||
image: hackfest3-mgmt | |||
count: '1' | |||
vm-flavor: | |||
vcpu-count: '1' | |||
memory-mb: '1024' | |||
storage-gb: '10' | |||
interface: | |||
- name: mgmtVM-eth0 | |||
position: '1' | |||
type: EXTERNAL | |||
virtual-interface: | |||
type: VIRTIO | |||
external-connection-point-ref: vnf-mgmt | |||
- name: mgmtVM-eth1 | |||
position: '2' | |||
type: INTERNAL | |||
virtual-interface: | |||
type: VIRTIO | |||
internal-connection-point-ref: mgmtVM-internal | |||
internal-connection-point: | |||
- id: mgmtVM-internal | |||
name: mgmtVM-internal | |||
short-name: mgmtVM-internal | |||
type: VPORT | |||
cloud-init-file: cloud-config.txt | |||
- id: dataVM | |||
name: dataVM | |||
image: hackfest3-mgmt | |||
count: '1' | |||
vm-flavor: | |||
vcpu-count: '1' | |||
memory-mb: '1024' | |||
storage-gb: '10' | |||
interface: | |||
- name: dataVM-eth0 | |||
position: '1' | |||
type: INTERNAL | |||
virtual-interface: | |||
type: VIRTIO | |||
internal-connection-point-ref: dataVM-internal | |||
- name: dataVM-xe0 | |||
position: '2' | |||
type: EXTERNAL | |||
virtual-interface: | |||
type: VIRTIO | |||
external-connection-point-ref: vnf-data | |||
internal-connection-point: | |||
- id: dataVM-internal | |||
name: dataVM-internal | |||
short-name: dataVM-internal | |||
type: VPORT | |||
vnf-configuration: | |||
juju: | |||
charm: simple | |||
initial-config-primitive: | |||
- seq: '1' | |||
name: config | |||
parameter: | |||
- name: ssh-hostname | |||
value: <rw_mgmt_ip> | |||
- name: ssh-username | |||
value: ubuntu | |||
- name: ssh-password | |||
value: osm4u | |||
- seq: '2' | |||
name: touch | |||
parameter: | |||
- name: filename | |||
value: '/home/ubuntu/first-touch' | |||
config-primitive: | |||
- name: touch | |||
parameter: | |||
- name: filename | |||
data-type: STRING | |||
default-value: '/home/ubuntu/touched' | |||
===NS diagram=== | |||
[[File:Hackfest simplecharm ns.JPG|500px]] | |||
===NS descriptor=== | |||
nsd:nsd-catalog: | |||
nsd: | |||
- id: hackfest-simplecharm-ns | |||
name: hackfest-simplecharm-ns | |||
short-name: hackfest-simplecharm-ns | |||
description: NS with 2 VNFs hackfest-simplecharm-vnf connected by datanet and mgmtnet VLs | |||
version: '1.0' | |||
logo: osm.png | |||
constituent-vnfd: | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index: '1' | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index: '2' | |||
vld: | |||
- id: mgmtnet | |||
name: mgmtnet | |||
short-name: mgmtnet | |||
type: ELAN | |||
mgmt-network: 'true' | |||
vim-network-name: mgmt | |||
vnfd-connection-point-ref: | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index-ref: '1' | |||
vnfd-connection-point-ref: vnf-mgmt | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index-ref: '2' | |||
vnfd-connection-point-ref: vnf-mgmt | |||
- id: datanet | |||
name: datanet | |||
short-name: datanet | |||
type: ELAN | |||
vnfd-connection-point-ref: | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index-ref: '1' | |||
vnfd-connection-point-ref: vnf-data | |||
- vnfd-id-ref: hackfest-simplecharm-vnf | |||
member-vnf-index-ref: '2' | |||
vnfd-connection-point-ref: vnf-data | |||
===Testing with OSM UI=== | |||
**Find hackfest3charmed-ns and click Instantiate NS Action | |||
**Complete the form | |||
***Add a name to the NS | |||
***Select the Datacenter where the NS will be deployed | |||
***Add SSH Key | |||
**Go to VNF Instances to see the instance | |||
**Click Show Info Action to see the mgmt IP address of the VNF | |||
**Connect to each VNF | |||
***ssh ubuntu@<IP> | |||
**Check that the cloud-config was executed | |||
*** The file ´/home/ubuntu/first-touch´ should exist | |||
**Go to Actions: Exec primitive in NS instances for testing VNF primitives | |||
***Vnf-member-index | |||
***Action | |||
***Parameter name | |||
***Parameter value |
Revision as of 07:57, 19 July 2018
Examples from the 3rd OSM Hackfest
Work material
Examples
Basic VNF and NS
- VNF package: hackfest1-vnf
- NS package: hackfest1-ns
- Image Ubuntu 1604: [1]
- Reference material: Presentation: creating a basic VNF and NS
VNF diagram
VNF descriptor
vnfd:vnfd-catalog: vnfd: - id: hackfest1-vnf name: hackfest1-vnf short-name: hackfest1-vnf version: '1.0' description: A simple VNF descriptor w/ one VDU logo: osm.png connection-point: - name: vnf-cp0 type: VPORT vdu: - id: hackfest1VM name: hackfest1VM image: ubuntu1604 count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: vdu-eth0 type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-cp0 mgmt-interface: cp: vnf-cp0
NS diagram
NS descriptor
nsd:nsd-catalog: nsd: - id: hackfest1-ns name: hackfest1-ns short-name: hackfest1-ns description: Simple NS with a single VNF and a single VL version: '1.0' logo: osm.png constituent-vnfd: - vnfd-id-ref: hackfest1-vnf member-vnf-index: '1' vld: - id: mgmtnet name: mgmtnet short-name: mgmtnet type: ELAN mgmt-network: 'true' vnfd-connection-point-ref: - vnfd-id-ref: hackfest1-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-cp0
Testing with OSM client
- Onboard VNF packages
- osm vnfd-create hackfest1_vnfd.tar.gz
- osm vnfd-list
- osm vnfd-show hackfest1-vnf
- Onboard NS packages
- osm nsd-create hackfest1_nsd.tar.gz
- osm nsd-list
- osm nsd-show hackfest1-ns
- Instantiate
osm ns-create --ns_name hf1 --nsd_name hackfest1-ns \ --vim_account <VIM_ACCOUNT_NAME>|<VIM_ACCOUNT_ID> \ --ssh_keys <KEY1_PUBKEY_FILE> \ --config '{vld: [ {name: mgmtnet, vim-network-name: <VIM_MGMT_NAME>} ] }'
- Check NS status
- osm ns-list
- osm ns-show hf1
- Check VNF instances to see the instance and get the mgmt IP address of the VNF
- osm vnf-list
- osm vnf-show ...
- Connect to the VNF
ssh -i <priv_key> ubuntu@<IP>
Testing with OSM UI
- Onboard VNF package
- Go to VNF packages
- Drag and drop the VNF package to the ...
- Onboard NS package
- Drag and drop the NS package to the ...
- Instantiate NS
- Go to NS packages
- In hackfest1-ns, click in “Actions: Instantiate NS”
- Complete the form
- Add a name to the NS instance
- Select the Datacenter where the NS will be deployed
- Specify in the config section a default VIM network name to map “mgmtnet”:
- Paste your public SSH key to get access to the VNF (VMs need to have cloud-init enabled, in this case the hackfest1 example has cloud-init)
- Connect to the VNF:
ssh -i <priv_key> ubuntu@<IP>
Multi-VDU VNF
- VNF package: hackfest2-vnf
- NS package: hackfest2-ns
- Image Ubuntu 1604: [2]
- Reference material: Modeling multi-VDU VNF
VNF diagram
VNF descriptor
vnfd:vnfd-catalog: vnfd: - id: hackfest2-vnf name: hackfest2-vnf short-name: hackfest2-vnf version: '1.0' description: A VNF consisting of 2 VDUs connected to an internal VL logo: osm.png connection-point: - id: vnf-mgmt name: vnf-mgmt short-name: vnf-mgmt type: VPORT - id: vnf-data name: vnf-data short-name: vnf-data type: VPORT mgmt-interface: cp: vnf-mgmt internal-vld: - id: internal name: internal short-name: internal type: ELAN internal-connection-point: - id-ref: mgmtVM-internal - id-ref: dataVM-internal vdu: - id: mgmtVM name: mgmtVM image: US1604 count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: mgmtVM-eth0 position: '1' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-mgmt - name: mgmtVM-eth1 position: '2' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: mgmtVM-internal internal-connection-point: - id: mgmtVM-internal name: mgmtVM-internal short-name: mgmtVM-internal type: VPORT - id: dataVM name: dataVM image: US1604 count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: dataVM-eth0 position: '1' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: dataVM-internal - name: dataVM-xe0 position: '2' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-data internal-connection-point: - id: dataVM-internal name: dataVM-internal short-name: dataVM-internal type: VPORT
NS diagram
NS descriptor
nsd:nsd-catalog: nsd: - id: hackfest2-ns name: hackfest2-ns short-name: hackfest2-ns description: NS with 2 VNFs connected by datanet and mgmtnet VLs version: '1.0' logo: osm.png constituent-vnfd: - vnfd-id-ref: hackfest2-vnf member-vnf-index: '1' - vnfd-id-ref: hackfest2-vnf member-vnf-index: '2' vld: - id: mgmtnet name: mgmtnet short-name: mgmtnet type: ELAN mgmt-network: 'true' vim-network-name: mgmt vnfd-connection-point-ref: - vnfd-id-ref: hackfest2-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-mgmt - vnfd-id-ref: hackfest2-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-mgmt - id: datanet name: datanet short-name: datanet type: ELAN vnfd-connection-point-ref: - vnfd-id-ref: hackfest2-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-data - vnfd-id-ref: hackfest2-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-data
Testing with OSM UI
- Onboard VNF package
- Go to VNF packages
- Drag and drop the VNF package to the ...
- Onboard NS package
- Drag and drop the NS package to the ...
- Instantiate NS
- Go to NS packages
- In hackfest2-ns, click in “Actions: Instantiate NS”
- Complete the form
- Add a name to the NS instance
- Select the Datacenter where the NS will be deployed
- Specify in the config section a default VIM network name to map “MGMTNET”:
- Paste your public SSH key to get access to the VNF (VMs need to have cloud-init enabled, in this case the hackfest1 example has cloud-init)
- Click the info button to see the mgmt IP address
- Connect to each VNF:
ssh osm@ <ip> (pwd:osm4u)
VNF with Day-0 configuration
- VNF package: hackfest3-vnf
- NS package: hackfest3-ns
- Image hackfest3-mgmt: [3]
- Reference material: Adding day-0 configuration to VNFs
VNF diagram
VNF descriptor
vnfd:vnfd-catalog: vnfd: - id: hackfest3-vnf name: hackfest3-vnf short-name: hackfest3-vnf version: '1.0' description: A VNF consisting of 2 VDUs connected to an internal VL, and one VDU with cloud-init logo: osm.png connection-point: - id: vnf-mgmt name: vnf-mgmt short-name: vnf-mgmt type: VPORT - id: vnf-data name: vnf-data short-name: vnf-data type: VPORT mgmt-interface: cp: vnf-mgmt internal-vld: - id: internal name: internal short-name: internal type: ELAN internal-connection-point: - id-ref: mgmtVM-internal - id-ref: dataVM-internal vdu: - id: mgmtVM name: mgmtVM image: hackfest3-mgmt count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: mgmtVM-eth0 position: '1' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-mgmt - name: mgmtVM-eth1 position: '2' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: mgmtVM-internal internal-connection-point: - id: mgmtVM-internal name: mgmtVM-internal short-name: mgmtVM-internal type: VPORT cloud-init-file: cloud-config.txt - id: dataVM name: dataVM image: hackfest3-mgmt count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: dataVM-eth0 position: '1' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: dataVM-internal - name: dataVM-xe0 position: '2' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-data internal-connection-point: - id: dataVM-internal name: dataVM-internal short-name: dataVM-internal type: VPORT
NS diagram
NS descriptor
nsd:nsd-catalog: nsd: - id: hackfest3-ns name: hackfest3-ns short-name: hackfest3-ns description: NS with 2 VNFs hackfest3-vnf connected by datanet and mgmtnet VLs version: '1.0' logo: osm.png constituent-vnfd: - vnfd-id-ref: hackfest3-vnf member-vnf-index: '1' - vnfd-id-ref: hackfest3-vnf member-vnf-index: '2' vld: - id: mgmtnet name: mgmtnet short-name: mgmtnet type: ELAN mgmt-network: 'true' vim-network-name: mgmt vnfd-connection-point-ref: - vnfd-id-ref: hackfest3-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-mgmt - vnfd-id-ref: hackfest3-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-mgmt - id: datanet name: datanet short-name: datanet type: ELAN vnfd-connection-point-ref: - vnfd-id-ref: hackfest3-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-data - vnfd-id-ref: hackfest3-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-data
Testing with OSM UI
- Select hackfest3-ns and instanciate it
- Complete the form
- Add a name to the NS
- Select the Datacenter where the NS will be deployed
- Add SSH key
- Go to the dashboard to see the instance and get the mgmt IP address of the VNF
- Connect to each VNF:
- ssh ubuntu@<IP>
- Check that the cloud-config file was executed
VNF with EPA requirements
- VNF package: hackfest4-vnf
- NS package: hackfest4-ns
- Image hackfest-pktgen: [4]
- Reference material: Modeling EPA capabilities in your VNF descriptor
VNF diagram
VNF descriptor
vnfd:vnfd-catalog: vnfd: - id: hackfest4-vnf name: hackfest4-vnf short-name: hackfest4-vnf version: '1.0' description: A VNF consisting of 2 VDUs with EPA capabilities connected to an internal VL, mgmtVM VDU with cloud-init logo: osm.png connection-point: - id: vnf-mgmt name: vnf-mgmt short-name: vnf-mgmt type: VPORT - id: vnf-data name: vnf-data short-name: vnf-data type: VPORT mgmt-interface: cp: vnf-mgmt internal-vld: - id: internal name: internal short-name: internal type: ELAN internal-connection-point: - id-ref: mgmtVM-internal - id-ref: dataVM-internal vdu: - id: mgmtVM name: mgmtVM image: hackfest3-mgmt count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' guest-epa: cpu-pinning-policy: DEDICATED cpu-thread-pinning-policy: PREFER mempage-size: LARGE numa-node-policy: mem-policy: STRICT node-cnt: '1' node: - id: '1' interface: - name: mgmtVM-eth0 position: '1' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-mgmt - name: mgmtVM-eth1 position: '2' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: mgmtVM-internal internal-connection-point: - id: mgmtVM-internal name: mgmtVM-internal short-name: mgmtVM-internal type: VPORT cloud-init-file: cloud-config.txt - id: dataVM name: dataVM image: hackfest-pktgen count: '1' vm-flavor: vcpu-count: '8' memory-mb: '4096' storage-gb: '10' guest-epa: cpu-pinning-policy: DEDICATED cpu-thread-pinning-policy: PREFER mempage-size: LARGE numa-node-policy: mem-policy: STRICT node-cnt: '1' node: - id: '1' interface: - name: eth0 position: '1' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: dataVM-internal - name: xe0 position: '2' type: EXTERNAL virtual-interface: type: SR-IOV external-connection-point-ref: vnf-data internal-connection-point: - id: dataVM-internal name: dataVM-internal short-name: dataVM-internal type: VPORT
NS diagram
NS descriptor
nsd:nsd-catalog: nsd: - id: hackfest4-ns name: hackfest4-ns short-name: hackfest4-ns description: NS with 2 VNFs hackfest4-vnf connected by datanet and mgmtnet VLs version: '1.0' logo: osm.png constituent-vnfd: - vnfd-id-ref: hackfest4-vnf member-vnf-index: '1' - vnfd-id-ref: hackfest4-vnf member-vnf-index: '2' vld: - id: mgmtnet name: mgmtnet short-name: mgmtnet type: ELAN mgmt-network: 'true' vim-network-name: mgmt vnfd-connection-point-ref: - vnfd-id-ref: hackfest4-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-mgmt - vnfd-id-ref: hackfest4-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-mgmt - id: datanet name: datanet short-name: datanet type: ELAN vnfd-connection-point-ref: - vnfd-id-ref: hackfest4-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-data - vnfd-id-ref: hackfest4-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-data
Testing with OSM UI
- Select hackfest4-ns and instanciate it
- Complete the form
- Add a name to the NS
- Select the Datacenter where the NS will be deployed
- SSH to the mgmtVM of one of the VNFs
- Check that cloud-init worked in mgmtVM
- Check interface names in mgmtVM
- Jump to dataVM
- ssh -i test4.pem<IP_dataVM>
- Check interface names in mgmtVM
- Run 'pktgen'
- SSH to the mgmtVM of the second VNF
- Check that cloud-init worked in mgmtVM
- Check interface names in mgmtVM
- Jump to dataVM
- ssh -i test4.pem<IP_dataVM>
- Check interface names in mgmtVM
- Run 'pktgen'
VNF with Day-1/Day-2 configuration (adding a charm)
- VNF package: hackfest_simplecharm_vnf
- NS package: hackfest_simplecharm_ns
- Image hackfest3-mgmt: [5]
- Reference material::
VNF diagram
VNF descriptor
vnfd:vnfd-catalog: vnfd: - id: hackfest-simplecharm-vnf name: hackfest-simplecharm-vnf short-name: hackfest-simplecharm-vnf version: '1.0' description: A VNF consisting of 2 VDUs connected to an internal VL, and one VDU with cloud-init logo: osm.png connection-point: - id: vnf-mgmt name: vnf-mgmt short-name: vnf-mgmt type: VPORT - id: vnf-data name: vnf-data short-name: vnf-data type: VPORT mgmt-interface: cp: vnf-mgmt internal-vld: - id: internal name: internal short-name: internal type: ELAN internal-connection-point: - id-ref: mgmtVM-internal - id-ref: dataVM-internal vdu: - id: mgmtVM name: mgmtVM image: hackfest3-mgmt count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: mgmtVM-eth0 position: '1' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-mgmt - name: mgmtVM-eth1 position: '2' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: mgmtVM-internal internal-connection-point: - id: mgmtVM-internal name: mgmtVM-internal short-name: mgmtVM-internal type: VPORT cloud-init-file: cloud-config.txt - id: dataVM name: dataVM image: hackfest3-mgmt count: '1' vm-flavor: vcpu-count: '1' memory-mb: '1024' storage-gb: '10' interface: - name: dataVM-eth0 position: '1' type: INTERNAL virtual-interface: type: VIRTIO internal-connection-point-ref: dataVM-internal - name: dataVM-xe0 position: '2' type: EXTERNAL virtual-interface: type: VIRTIO external-connection-point-ref: vnf-data internal-connection-point: - id: dataVM-internal name: dataVM-internal short-name: dataVM-internal type: VPORT vnf-configuration: juju: charm: simple initial-config-primitive: - seq: '1' name: config parameter: - name: ssh-hostname value: <rw_mgmt_ip> - name: ssh-username value: ubuntu - name: ssh-password value: osm4u - seq: '2' name: touch parameter: - name: filename value: '/home/ubuntu/first-touch' config-primitive: - name: touch parameter: - name: filename data-type: STRING default-value: '/home/ubuntu/touched'
NS diagram
NS descriptor
nsd:nsd-catalog: nsd: - id: hackfest-simplecharm-ns name: hackfest-simplecharm-ns short-name: hackfest-simplecharm-ns description: NS with 2 VNFs hackfest-simplecharm-vnf connected by datanet and mgmtnet VLs version: '1.0' logo: osm.png constituent-vnfd: - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index: '1' - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index: '2' vld: - id: mgmtnet name: mgmtnet short-name: mgmtnet type: ELAN mgmt-network: 'true' vim-network-name: mgmt vnfd-connection-point-ref: - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-mgmt - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-mgmt - id: datanet name: datanet short-name: datanet type: ELAN vnfd-connection-point-ref: - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index-ref: '1' vnfd-connection-point-ref: vnf-data - vnfd-id-ref: hackfest-simplecharm-vnf member-vnf-index-ref: '2' vnfd-connection-point-ref: vnf-data
Testing with OSM UI
- Find hackfest3charmed-ns and click Instantiate NS Action
- Complete the form
- Add a name to the NS
- Select the Datacenter where the NS will be deployed
- Add SSH Key
- Go to VNF Instances to see the instance
- Click Show Info Action to see the mgmt IP address of the VNF
- Connect to each VNF
- ssh ubuntu@<IP>
- Check that the cloud-config was executed
- The file ´/home/ubuntu/first-touch´ should exist
- Go to Actions: Exec primitive in NS instances for testing VNF primitives
- Vnf-member-index
- Action
- Parameter name
- Parameter value