Scale-in/Scale-out commands can be only triggered from CLI. When they are triggered...
[osm/Features.git] / Release5 / OSM_platform_resiliency_to_single_component_failure.md
1 # OSM platform resiliency to single component failure #
2
3 ## Proposer ##
4 - Gerardo Garcia (Telefonica)
5 - Alfonso Tierno (Telefonica)
6 - Francisco Javier Ramon (Telefonica)
7
8 ## Type ##
9 **Feature**
10
11 ## Target MDG/TF ##
12 SO, RO, VCA, UI
13
14 ## Description ##
15 **This feature obsoletes feature #666: 
16 https://osm.etsi.org/gerrit/#/c/666/**
17
18 The NFV Orchestrator becomes a critical component for the operator in a 
19 production environment. As such, it should be capable of recovering from 
20 unexpected failures of its components, via a combination of techniques. In this 
21 case, it should be possible to keep the system alive in case of failure of a 
22 single component (e.g. active-standby redundancy).
23
24 As part of this resilience strategy it might be useful identifying:
25 - Which sub-components (inside each of the current modules) are intended to 
26 store permanent information (databases, repositories) or should be considered 
27 stateful, and devise specific HA strategies for them.
28 - Which sub-components are stateless (or can recover efficiently their state 
29 from databases or stateful components) and devise bootstrap and, if applicable, 
30 load balancing or active-standby strategies for them.
31
32 ## Demo or definition of done ##
33 In a running OSM system with an instantiated NS, an abrupt poweroff is forced 
34 in the container where one OSM component is running. After that event, the OSM 
35 system keeps working and can continue the operation of the running NS. This 