From e3a7087d9bf9591aa46e86e652cd0728adf5d010 Mon Sep 17 00:00:00 2001 From: almagia Date: Wed, 3 Apr 2019 12:26:38 +0100 Subject: [PATCH] Deleting unused files Change-Id: I6c7b861f02091c4b68bd04eff62b9614c6cf2571 --- models/yang/mano-rift-groupings.yang | 95 ------- models/yang/rw-pb-ext.yang | 358 --------------------------- 2 files changed, 453 deletions(-) delete mode 100644 models/yang/mano-rift-groupings.yang delete mode 100644 models/yang/rw-pb-ext.yang diff --git a/models/yang/mano-rift-groupings.yang b/models/yang/mano-rift-groupings.yang deleted file mode 100644 index 7788724..0000000 --- a/models/yang/mano-rift-groupings.yang +++ /dev/null @@ -1,95 +0,0 @@ -/* - * - * Copyright 2016-2017 RIFT.IO Inc - * - * Licensed under the Apache License, Version 2.0 (the "License"); - * you may not use this file except in compliance with the License. - * You may obtain a copy of the License at - * - * http://www.apache.org/licenses/LICENSE-2.0 - * - * Unless required by applicable law or agreed to in writing, software - * distributed under the License is distributed on an "AS IS" BASIS, - * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. - * See the License for the specific language governing permissions and - * limitations under the License. - * - * - */ - - module mano-rift-groupings -{ - namespace "urn:ietf:params:xml:ns:yang:nfvo:mano-rift-groupings"; - prefix "mano-rift"; - - import mano-types { - prefix "manotypes"; - } - - grouping custom-meta-data { - description "Grouping for instance-specific meta data"; - list custom-meta-data { - description - "List of meta-data to be associated with the instance"; - key "name"; - leaf name { - description "Name of the meta-data parameter"; - type string; - } - - leaf data-type { - description "Data-type the meta-data parameter"; - type manotypes:meta-data-type; - default "STRING"; - } - - leaf value { - description "Value of the meta-data parameter"; - type string; - } - - leaf destination { - description "Type of input parameter"; - type enumeration { - enum "CLOUD_INIT"; - enum "CLOUD_METADATA"; - } - default "CLOUD_METADATA"; - } - } - } - - grouping volume-info-additions { - leaf boot-volume { - description "This flag indicates if this is boot volume or not"; - type boolean; - } - - leaf boot-priority { - description "Boot priority associated with volume"; - type int32; - } - } - - grouping http-end-point-additions { - leaf data { - description - "This is the data to be sent with POST "; - type string; - } - } - - grouping ssh-key-generated { - container ssh-key-generated { - description "SSH key pair generated for this NS"; - leaf public-key { - description "Public key generated"; - type string; - } - leaf private-key-file { - description "Path to the private key file"; - type string; - } - } - } -} diff --git a/models/yang/rw-pb-ext.yang b/models/yang/rw-pb-ext.yang deleted file mode 100644 index 1b90153..0000000 --- a/models/yang/rw-pb-ext.yang +++ /dev/null @@ -1,358 +0,0 @@ -/* STANDARD_RIFT_IO_COPYRIGHT */ - -/** - * @file rw-pb-ext.yang - * @author Tim Mortsolf, Anil Gunturu, Tom Seidenberg - * @date 2013/03/21 - * @brief RiftWare yang to protobuf conversion extensions - */ - -module rw-pb-ext -{ - namespace "http://riftio.com/ns/riftware-1.0/rw-pb-ext"; - prefix "rwpb"; - - revision 2014-03-28 { - description - "Initial revision."; - reference - "RIFT yang extensions for converting yang files to Google - Protocol Buffers (protobuf) using rift protoc-c extensions."; - } - - extension msg-new { - argument "typename"; - description - "Generate an equivalent, top-level, protobuf message for this - container, list, rpc input, rpc output, or notification. The - argument is the name of the protobuf message type. Allowed - values are valid C identifiers. - - The protobuf definition will only be generated when processing - the same module that defines the yang object - a duplicate will - not be generated when importing reusing a yang object via uses, - or when importing the module."; - } - - extension msg-name { - argument "typename"; - description - "Change the name of an embedded protobuf message type for this - container or list. Allowed values are valid C identifiers. - - In lieu of this extension, embedded protobuf message typenames - are based on the fieldname, and further mangled by removing - underscores and CamelCased at underscore boundaries. This - extension allows the automatic mangling procedure to be - overridden. - - This extension is incompatible with msg-new, which already - defines the typename for top-level messages. Use this extension - solely for embedded messages."; - } - - extension msg-flat { - argument "selection"; - description - "Set the protobuf message rw_msgopts flat option on a container - or list statement. Allowed values are 'true', 'false', and - 'auto'. The default is 'false' for top-level messages, and - 'auto' for embedded messages. If 'auto' is specified, the - behavior is the same as the enclosing container or list. - - Unless overridden, this extension effectively applies to all - enclosed descendent container and list statements. Flatness will - be required by the protobuf compilation step."; - } - - extension msg-tag-base { - argument "value"; - description - "Specify a base tag value for a container, list, grouping, or - uses statement. Field tags may be specified relative to this - base. Allowed values are positive - decimal integers."; - // ATTN: would really like to specify field-relative in uses! - } - -/* - extension msg-tag-reserve { - argument "value"; - description - "Reserve space in the tag numbering for future expansion of the - enclosing grouping, container, or choice. Must be a positive - decimal integer. Choose carefully, as you cannot increase the - value at a later time."; - } -*/ - - extension msg-proto-max-size { - argument "value"; - description - "Specify the maximum size of this message in the C structure or - so in bytes. Allowed values are positive decimal integers."; - } - - extension msg-typedef { - argument "typename"; - description - "Create a prototbuf-c message typedef for the original, base - definition of the container, list, grouping, rpc input, rpc - output, or notification. Allowed values are valid C identifiers. - - typename will be appended to the mangeled protobuf package name - and an underscore, to ensure name uniqueness across the global - schema. - - The typedef will only be generated when processing - the same module that defines the yang object - a duplicate will - not be generated when importing reusing a yang object via uses, - or when importing the module."; - } - - extension field-name { - argument "fieldname"; - description - "Change the name of the element to fieldname, when converting the - object to protobuf. Allowed values are valid C identifiers. - - In lieu of this extension, element names will be used as-is, if - possible, or mangled to fit in the C identifier character space - (invalid C identifier characters will be replaced with - underscore). This extension allows the automatic mangling - procedure to be overridden."; - } - - extension field-inline { - argument "selection"; - description - "Set the protobuf field 'inline' option on a container, list, - leaf-list, or leaf statement. Allowed values are 'true', - 'false', and 'auto'. If 'auto' is specified, the behavior is - controlled by the enclosing container or list's protobuf-msg-flat - setting. - - When applied to a container or list statement, this extension is - inherited by all enclosed objects, unless overridden."; - } - - extension field-inline-max { - argument "limit"; - description - "Set the protobuf field 'inline_max' option for list and - leaf-list statements. Allowed values are a positive decimal - integer, 'yang', or 'none'. Example limits: - - '64' - 'yang' - 'none' - - If 'none' is specified, then the inline_max protobuf extension - will not be used. - - If 'yang' is specified, then the number of elements specified in - the yang 'max-elements' statement is used. If there is no - 'max-elements' statement, the behavior defaults to 'none'. - - If a decimal integer is specified, that number is used as the - maximum length. - - If this extension is not specified, the behavior defaults to - 'yang'. Descendant list and leaf-list objects do not inherit - this extension."; - } - - extension field-string-max { - argument "limit"; - description - "Set the protobuf field 'string_max' option for a leaf or - leaf-list of type string, binary, leafref, identityref, or - instance-identifier. Allowed values are a positive decimal - integer, 'yang', or 'none'. An optional encoding specifier may - also be specified, as octet or utf8, which specifies how - characters are counted. If specified, the encoding must come - first. Example limits: - - 'octet 64' - 'utf8 20' - 'utf8 yang' - 'utf8' - '128' - 'none' - - If 'none' is specified, then the string_max protobuf extension - will not be used. 'none' cannot be combined with 'octet' or - 'utf8'. - - If 'yang' is specified, the yang type must be string or binary. - If the yang type includes the length statement, then the - statements maximum length is used as the length. Otherwise, - behavior defaults to 'none'. - - If a decimal integer is specified, that number is used as the - length. - - The encoding specifiers are used to determine the actual number - of bytes used in the protobuf extension. If the 'octet' - specifier is used, then the maximum length is used literally as - the byte length. If the 'utf8' specified is used, then the - maximum length is considered to be in terms of worst-case UTF-8 - characters, in which case the protobuf byte length will actually - be 4 times the specified length. - - For string and binary types, the default encoding is 'octet'. - For the remaining types, the default encoding is 'utf8', - reflecting those types fundemental description as XML entities - assumed to be encoded in UTF-8. - - If this extension is not specified, then the default is 'yang' - for string and binary, and 'none' for the other types. This - extension cannot be specified on aggregate objects, and so it - cannot be inherited."; - } - - extension field-tag { - argument "value"; - description - "Set the protobuf field tag. Allowed values are a positive - decimal integer, 'auto', a base-relative addition expression, or - a field-relative addition expression. - - If a decimal integer is specified, then the tag is set to the - specified number. You should avoid using this form in a - grouping, because you may not be able to guarantee uniqueness - across all the uses of the group. However, the syntax will be - allowed. - - A base-relative addition expression allows the tag of a field to - be defined in terms of the base tag of an enclosing grouping, - container, list, or uses statement. The expression has the form - '+NUMBER', where NUMBER is the value to add to the base to derive - the current field's tag. - - A field-relative addition expression allows the tag of one field - to be defined in terms of another field. The expression has the - form 'NAME+NUMBER', where NAME is the name of the other field, - and NUMBER is the value to add to the other fields tag to derive - the current field's tag. - - If this extension is not specified, the default behavior is - 'auto'."; - } - - extension field-type { - argument "type"; - description - "Override the default protobuf field type mapping for a leaf or - leaf-list type, and use the specified protobuf type instead. - - Allowed values are any of the Protobuf scalar types, as - restricted by the yang leaf type: - - +---------------------------+-------------------------------+ - | (pseudo) yang leaf type | (pseudo) protobuf scalar type | - |---------------------------+-------------------------------+ - | int8, int16, int32 | int32, sint32, sfixed32, auto | - +---------------------------+-------------------------------+ - | int64 | int64, sint64, sfixed64, auto | - +---------------------------+-------------------------------+ - | uint8, uint16, uint32 | uint32, fixed32, auto | - +---------------------------+-------------------------------+ - | uint64 | uint64, fixed64, auto | - +---------------------------+-------------------------------+ - | decimal | uint64, sint64, int64, | - | | fixed64, sfixed64, | - | | float, double, auto | - +---------------------------+-------------------------------+ - | empty, boolean | bool, auto | - +---------------------------+-------------------------------+ - | string, leafref, | string, auto | - | identityref, | | - | instance-identifier, | | - | anyxml | | - +---------------------------+-------------------------------+ - | bits, binary | bytes, auto | - +---------------------------+-------------------------------+ - - If 'auto' is specified, the default conversion will be used. The - protobuf pseudo-type utf8 is equivalent to string, except that - length limits will be adjusted in protobuf extentions to allow - the string to be composed entirely of the maximum sized UTF-8 - multibyte characters (byte length is 4 times larger than the - character length)."; - } - - extension field-c-type { - argument "type"; - description - "Override the default protoc-c C-language type mapping for a leaf - or leaf-list type, and use the specified C type instead."; - } - - /* ATTN: Stop using this extension? */ - extension package-name { - argument "pkgname"; - description - "Specifies the name of the package name in the generated .proto - file on a module statement The argument is the name of the - package-name. Allowed values are valid C identifiers When - package-name is not specified the generated package name defaults - to the Yang module name"; - } - - extension application-request-point { - description - "This extension is used temporarily until the config and data portions - are split into different namespaces and keyspecs. This allows - applications to provide data at a keyspec, and request config at a - different level"; - } - - extension enum-name { - argument "enumname"; - description - "Use the specified name for the enum enumerator in the .proto - instead of the default mangled name of the yang identifer. - If there is a name conflict with other enum name either specified - explicitly or generated one, the yangpbc conversion will fail. - Allowed values are valid C identifiers."; - } - - extension enum-type { - argument "enumtypename"; - description - "Use the specified name for the enum type in the .proto instead - of the default mangled name of the yang identifier. If there is - a name conflict with another enum type, either auto-generated or - explicitly specified one, the yangpbc conversion will fail. - Allowed values are valid C identifiers."; - } - - extension file-pbc-include { - argument "pathstring"; - description - "A module level extension to specify the include files for pb-c.h - when any rift specific c-types are used. This extension can - occur multiple times as a child of module statement. The value - should be a valid path string."; - } - - extension field-merge-behavior { - argument "value"; - description - "An extension for controlling the merge done for listy types - during upacking of protobuf. It can take 3 different value: - - 1) default: The default is whatever protobuf-c does today - (for keyed lists, the default is equivalent to by-keys). - - 2) by-keys: allowed on keyed lists (and leaf-lists): merge - elements with matching key. - - 3) none: allowed on keyed lists (and leaf-lists): do not - attempt to merge elements. This must ONLY be used when it - is known or expected that the proto message would contain - large number of list items."; - } - -} // rw-pb-ext -- 2.17.1