Selective support of MAC address selection, preserving infrastructure and descriptor... 51/5651/2
authortierno <alfonso.tiernosepulveda@telefonica.com>
Fri, 3 Nov 2017 22:44:52 +0000 (23:44 +0100)
committergarciadeblas <gerardo.garciadeblas@telefonica.com>
Sat, 14 Nov 2020 00:24:22 +0000 (01:24 +0100)
Change-Id: I51f194530291ccbc1511253ac6d9fbbcc8744a7e
Signed-off-by: tierno <alfonso.tiernosepulveda@telefonica.com>
Release4/Selective_support_of_MAC_address_selection_preserving_infrastructure_and....md [new file with mode: 0644]

diff --git a/Release4/Selective_support_of_MAC_address_selection_preserving_infrastructure_and....md b/Release4/Selective_support_of_MAC_address_selection_preserving_infrastructure_and....md
new file mode 100644 (file)
index 0000000..453bcb3
--- /dev/null
@@ -0,0 +1,65 @@
+# Selective support of MAC address selection, preserving infrastructure and 
+descriptor coherency #
+## Proposer ##
+- Pablo Montes (Telefonica)
+- Antonio Lopez (Telefonica)
+- Gerardo Garcia (Telefonica)
+- Alfonso Tierno (Telefonica)
+- Francisco Javier Ramon (Telefonica)
+## Type ##
+**Feature**
+## Target MDG/TF ##
+IM-NBI, SO, RO
+## Description ##
+Many legacy, non cloud-native, VNFs assume that the VIM can provide specific 
+MAC addresses to specific interfaces of their VDUs/VMs. 
+
+
+This feature request aims to provide the same support to model the same 
+behaviour that some of the commonest VIMs already provide for some interface 
+types (paravirtualized interfaces and, optionally, SR-IOV). 
+As in the case of IP profiles, a coherency check is mandatory to prevent that 
+these MAC addresses created by the VIM can create conflicts between different 
+instances of the same NS/VNF or between VNFs interconnected in a NS.
+In order to guarantee that coherency, MAC addresses can only be set in a 
+descriptor where they correspond to VLs or CPs that are considered 
+″internal″ to the corresponding VNFD or NSD. Thus:
+* At VNFD level, a specific MAC address can be set only in internal 
+interfaces/CP.
+* At NSD level, same rules as above would apply, but in the context of a NS 
+template (now, many ″external″ VNFD’s CPs or VLDs might become 
+″internal″ for the NSD).
+* If required, parameters passed at the time of instantiation would allow to 
+set MAC addresses of external CP of the NS.
+It must be noted that in those CPs that are not completely handled by the VIM, 
+but by the VNFs + SDN controllers (with SR-IOV), this feature might not be 
+feasible. 
+## Demo or definition of done ##
+1. Create a VNFD (VNFD_1) with 2 VDUs, each of them with 2 interfaces (besides 
+mgmt). One interface of each VDUs is connected to an internal VL between both 
+VDUs. This VL will have DHCP enabled and a specific CIDR. The VDU interfaces 
+connected to the internal VL should have a specific MAC address assigned in the 
+own descriptor. The other remaining interfaces, should be external CP.
+2. Create an NSD (NSD_1) that includes the VNFD and exposes its external CP as 
+external CP of the NS.
+3. Instantiate NSD_1 (assuming that the external networks have DHCP enabled) 
+and check that:
+  * The MAC addresses are set according to descriptor.
+  * The NS instance works as expected.
+4. Create a second NSD (NSD_2) with 2 VNFD_1. One interface of each VNF is 
+connected to an internal VL between both. This VL will have DHCP enabled and a 
+specific CIDR. The VNF interfaces connected to the internal VL should have 
+specific MAC addresses assigned in the own NS descriptor.
+5. Instantiate NSD_2 and repeat same checks as in step 3.
+6. Instantiate NSD_2 but setting the IP addresses of some external CP of the 
+NS. Repeat same checks as in step 3.
+7. Check that it is not possible to change VNF_1, NS_1 or NS_2 to set MAC 
+addresses of external interfaces/CP and onboard them successfully in the system.