def __init__(self, net):
self.net = net
- def network_action_start(self, vnf_src_name, vnf_dst_name, vnf_src_interface=None, vnf_dst_interface=None):
+ def network_action_start(self, vnf_src_name, vnf_dst_name, vnf_src_interface=None, vnf_dst_interface=None, weight=None):
# call DCNetwork method, not really datacenter specific API for now...
# provided dc name needs to be part of API endpoint
# no check if vnfs are really connected to this datacenter...
logging.debug("RPC CALL: network chain start")
try:
c = self.net.setChain(
- vnf_src_name, vnf_dst_name, vnf_src_interface, vnf_dst_interface)
+ vnf_src_name, vnf_dst_name,
+ vnf_src_interface=vnf_src_interface,
+ vnf_dst_interface=vnf_dst_interface,
+ weight=weight)
return str(c)
except Exception as ex:
logging.exception("RPC error.")
return ex.message
- def network_action_stop(self, vnf_src_name, vnf_dst_name, vnf_src_interface=None, vnf_dst_interface=None):
+ def network_action_stop(self, vnf_src_name, vnf_dst_name, vnf_src_interface=None, vnf_dst_interface=None, weight=None):
# call DCNetwork method, not really datacenter specific API for now...
# provided dc name needs to be part of API endpoint
# no check if vnfs are really connected to this datacenter...
logging.debug("RPC CALL: network chain stop")
try:
c = self.net.setChain(
- vnf_src_name, vnf_dst_name, vnf_src_interface, vnf_dst_interface, cmd='del-flows')
+ vnf_src_name, vnf_dst_name,
+ vnf_src_interface=vnf_src_interface,
+ vnf_dst_interface=vnf_dst_interface,
+ cmd='del-flows',
+ weight=weight)
return c
except Exception as ex:
logging.exception("RPC error.")
logging.exception("RPC error.")
return ex.message
- # setup the rate measurement for a vnf interface
- def monitor_setup_rate_measurement(self, vnf_name, vnf_interface, metric):
- logging.debug("RPC CALL: get rate")
- try:
- c = self.net.monitor_agent.setup_rate_measurement(vnf_name, vnf_interface, metric)
- return c
- except Exception as ex:
- logging.exception("RPC error.")
- return ex.message
-
- # get egress(default) or ingress rate of a vnf
- def monitor_get_rate(self, vnf_name, vnf_interface, metric):
- logging.debug("RPC CALL: get rate")
+ # remove the rate measurement for a vnf interface
+ def stop_metric(self, vnf_name, vnf_interface, metric):
+ logging.debug("RPC CALL: stop metric")
try:
- c = self.net.monitor_agent.get_rate(vnf_name, vnf_interface, metric)
+ c = self.net.monitor_agent.stop_metric(vnf_name, vnf_interface, metric)
return c
except Exception as ex:
logging.exception("RPC error.")
return ex.message
-