Changes insufficient data validation in alarms to account for metric results 0.0
Change-Id: Ia67e54ced6f5885ecd875c8a94529b9384fa46b2
Signed-off-by: Benjamin Diaz <bdiaz@whitestack.com>
diff --git a/osm_mon/evaluator/service.py b/osm_mon/evaluator/service.py
index 3865b17..20bb0ad 100644
--- a/osm_mon/evaluator/service.py
+++ b/osm_mon/evaluator/service.py
@@ -71,7 +71,7 @@
alarm: Alarm):
log.debug("_evaluate_metric")
metric_value = self._get_metric_value(nsr_id, vnf_member_index, vdur_name, metric_name)
- if not metric_value:
+ if metric_value is None:
log.warning("No metric result for alarm %s", alarm.id)
self.queue.put((alarm, AlarmStatus.INSUFFICIENT))
else: